Page view 25
Oven
Injector
INSTALLATION INSTRUCTIONS
26
Burner
Grill
150
110
NATURAL GAS (G20)
Kitchen Worktop Thickness
30mm
45mm
55mm
Worktop Thickness + 15mm
40mm
40mm +
Note: The hob may project up to the worktop thickness + 30mm
provided this is at least 100mm behind the front of the oven.
Maximum Hob Depth From Worktop
Surface Down
Heat Input
3.7 kW
2.5 kW
TECHNICAL DATA
Gas connection Rp
1/2
(
1/2
" BSP female)
Gas supply G20 at 20 mbar.
Pressure test point Grill injector
Electrical connection Flexible cord fitted with a 3 pin 13 amp plug.
230 - 240 a.c. 50H
Z
3A fuse
1. GENERAL
The appliance is designed for mounting at a safe level into an oven housing
which must be secured to the backing wall. The appliance can be installed in a
tall cabinet or alternatively under a worktop with or without a hob unit above.
It is important that the installation instructions for the hob are strictly observed.
Where a hob is fitted above the oven unit the electrical connection for the hob should be made
with an 85˚ C high temperature flexible cord to table 15 of BS 6141.
A gas hob fitted above the oven unit should be connected to the gas supply with rigid
tubing.